Sml
Requirements
To use this plugin for reading data from your smart power meter hardware you need to have a serial or network interface connected to your hardware.
Most smart power meter hardware have an optical interface on the front of the casis. These are two IR LEDs which can be used to read data from the power meter hardware (e.g. by using a optical reader connected to an USB port).
Hardware
The plugin was tested with the following hardware:
Hager EHZ363Z5
Hager EHZ363W5
EHM eHZ-GW8 E2A 500 AL1
EHM eHZ-ED300L
Configuration
plugin.yaml
sml:
class_name: Sml
class_path: plugins.sml
serialport: /dev/ttyUSB0
# host: 192.168.2.1
# port: 1234
# device: raw | hex | <known-device>
The plugin reads data from smart power meter hardware by using a serial interface (e.g. /dev/ttyUSB0) or by connecting to a host/port. It reads messages using the SML (Smart Message Language) protocol. If you want to know more about the protocol see here.
Usually the smart power meter hardware is sending status information every few seconds via the interface which is read by the plugin. This status information, consisting of a SML_PublicOpen and SML_GetList message, provides the current power status and details (e.g. total power consumed, current power).
All status values retrieved by these messages have a unique identifier which is called OBIS code. This can be used to identify the meaning of the value returned.
Description of the attributes:
serialport
- defines the serial port to use to read data fromhost
- instead of serial port you can use a network connectionport
- additionally to the host configuration you can specify a portdevice
- specifies connected device to indicate pre-processing
The device
attribute can be used to specify the connected device and the
kind of data delivery. Since different devices (e.g. when connecting the
power meter device via a LAN gateway) the data can be differently. Usually
when connecting a serial device directly to the power meter device the
raw data can be directly used with this plugin. Some other devices needs
to be configured.
The following kinds of device types are supported:
raw
- this is the default and means the raw SML binary data is send to the pluginhex
- can be used in case the SML data is encoded as hex stringor a known device name
In case you have a known device you can also specify this and the plugin knows which data pre-processing is required. The following known devices are supported:
smart-meter-gateway-com-1
- The Smart Meter Gateway COM-1 http://shop.co-met.info/artikeldetails/kategorie/Smart-Metering/artikel/smart-meter-gateway-com-1.html
items.yaml
You can assign a value retrieved by the plugin to some of your items by using the OBIS identifier.
Here’s a list of OBIS codes which may be useful:
129-129:199.130.3*255 - Manufacturer
1-0:0.0.9*255 - ServerId / serial number
1-0:1.8.0*255 - Total kWh consumption (in)
1-0:1.8.1*255 - Tariff 1 kWh consumption (in)
1-0:1.8.2*255 - Tariff 2 kWh consumption (in)
1-0:2.8.0*255 - Total kWh delivery (out)
1-0:2.8.1*255 - Tariff 1 kWh delivery (out)
1-0:2.8.2*255 - Tariff 2 kWh delivery (out)
1-0:16.7.0*255 - Current Delivery Watt (out)
Instead of assigning the value for a given OBIS code, you can also assign meta information for an OBIS code which is included in the data packet sent from the power meter device.
For the complete list of properties for an OBIS code see below. They can be
assigned to items using the sml_prop
attribute. In case one property is not
available or explicitely unset it’s value will be set to None.
The following properties are available:
objName
- this is the OBIS code as string / binary datastatus
- a status valuevalTime
- the time of value (as seconds of unit start or as timestamp)unit
- identifies the value’s unit (e.g. W, kWh, V, A, …)scaler
- the scaler (10-factor shift) used to calculate the real valuevalue
- the valuesignature
- the signature to protect the payload
Additionally the following attributes will be calculated and also be provided:
obis
- the OBIS code as stringvalueReal
- the real value when including the scaler calculationunitName
- the name of the unit
sml_obis
This assigns the value for the given OBIS code to the item.
sml_obis: 1-0:1.8.0*255
sml_prop
Use this to assign other information for an OBIS code to the item. When not
explicitely specified it defaults to valueReal
.
sml_prop: unitName
Example
Here you can find a sample configuration:
power:
home:
total:
type: num
sml_obis: 1-0:1.8.0*255
current:
type: num
sml_obis: 1-0:16.7.0*255
unit:
type: num
sml_obis: 1-0:16.7.0*255
sml_prop: unitName
logic.yaml
Currently there is no logic configuration for this plugin.
Methodes