Sml

Requirements

To use this plugin for reading data from your smart power meter hardware you need to have a serial or network interface connected to your hardware.

Most smart power meter hardware have an optical interface on the front of the casis. These are two IR LEDs which can be used to read data from the power meter hardware (e.g. by using a optical reader connected to an USB port).

Hardware

The plugin was tested with the following hardware:

  • Hager EHZ363Z5

  • Hager EHZ363W5

  • EHM eHZ-GW8 E2A 500 AL1

  • EHM eHZ-ED300L

Configuration

plugin.yaml

sml:
  class_name: Sml
  class_path: plugins.sml
  serialport: /dev/ttyUSB0
  # host: 192.168.2.1
  # port: 1234
  # device: raw | hex | <known-device>

The plugin reads data from smart power meter hardware by using a serial interface (e.g. /dev/ttyUSB0) or by connecting to a host/port. It reads messages using the SML (Smart Message Language) protocol. If you want to know more about the protocol see here.

Usually the smart power meter hardware is sending status information every few seconds via the interface which is read by the plugin. This status information, consisting of a SML_PublicOpen and SML_GetList message, provides the current power status and details (e.g. total power consumed, current power).

All status values retrieved by these messages have a unique identifier which is called OBIS code. This can be used to identify the meaning of the value returned.

Description of the attributes:

  • serialport - defines the serial port to use to read data from

  • host - instead of serial port you can use a network connection

  • port - additionally to the host configuration you can specify a port

  • device - specifies connected device to indicate pre-processing

The device attribute can be used to specify the connected device and the kind of data delivery. Since different devices (e.g. when connecting the power meter device via a LAN gateway) the data can be differently. Usually when connecting a serial device directly to the power meter device the raw data can be directly used with this plugin. Some other devices needs to be configured.

The following kinds of device types are supported:

  • raw - this is the default and means the raw SML binary data is send to the plugin

  • hex - can be used in case the SML data is encoded as hex string

  • or a known device name

In case you have a known device you can also specify this and the plugin knows which data pre-processing is required. The following known devices are supported:

  • smart-meter-gateway-com-1 - The Smart Meter Gateway COM-1 http://shop.co-met.info/artikeldetails/kategorie/Smart-Metering/artikel/smart-meter-gateway-com-1.html

items.yaml

You can assign a value retrieved by the plugin to some of your items by using the OBIS identifier.

Here’s a list of OBIS codes which may be useful:

  • 129-129:199.130.3*255 - Manufacturer

  • 1-0:0.0.9*255 - ServerId / serial number

  • 1-0:1.8.0*255 - Total kWh consumption (in)

  • 1-0:1.8.1*255 - Tariff 1 kWh consumption (in)

  • 1-0:1.8.2*255 - Tariff 2 kWh consumption (in)

  • 1-0:2.8.0*255 - Total kWh delivery (out)

  • 1-0:2.8.1*255 - Tariff 1 kWh delivery (out)

  • 1-0:2.8.2*255 - Tariff 2 kWh delivery (out)

  • 1-0:16.7.0*255 - Current Delivery Watt (out)

Instead of assigning the value for a given OBIS code, you can also assign meta information for an OBIS code which is included in the data packet sent from the power meter device.

For the complete list of properties for an OBIS code see below. They can be assigned to items using the sml_prop attribute. In case one property is not available or explicitely unset it’s value will be set to None.

The following properties are available:

  • objName - this is the OBIS code as string / binary data

  • status - a status value

  • valTime - the time of value (as seconds of unit start or as timestamp)

  • unit - identifies the value’s unit (e.g. W, kWh, V, A, …)

  • scaler - the scaler (10-factor shift) used to calculate the real value

  • value - the value

  • signature - the signature to protect the payload

Additionally the following attributes will be calculated and also be provided:

  • obis - the OBIS code as string

  • valueReal - the real value when including the scaler calculation

  • unitName - the name of the unit

sml_obis

This assigns the value for the given OBIS code to the item.

sml_obis: 1-0:1.8.0*255

sml_prop

Use this to assign other information for an OBIS code to the item. When not explicitely specified it defaults to valueReal.

sml_prop: unitName

Example

Here you can find a sample configuration:

power:

    home:

        total:
            type: num
            sml_obis: 1-0:1.8.0*255

        current:
            type: num
            sml_obis: 1-0:16.7.0*255

        unit:
            type: num
            sml_obis: 1-0:16.7.0*255
            sml_prop: unitName

logic.yaml

Currently there is no logic configuration for this plugin.