Modbus Plugin for Kostal inverters
Version 1.6.3
This plugin connects your Kostal inverter (https://www.kostal-solar-electric.com/) via ModBus with SmarthomeNG.
read out all inverter data
Change history
support for pymodbus 2 dropped
Requirements needed software
Python >= 3.8
pip install pymodbus
SmarthomeNG >= 1.8.0
Supported Inverters
Inverter |
Supported |
Tested |
---|---|---|
PLENTICORE plus 4.2 |
yes |
no |
PLENTICORE plus 5.5 |
yes |
no |
PLENTICORE plus 7.0 |
yes |
yes |
PLENTICORE plus 8.5 |
yes |
yes |
PLENTICORE plus 10 |
yes |
yes |
PIKO IQ 4.2 |
yes |
no |
PIKO IQ 5.5 |
yes |
no |
PIKO IQ 7.0 |
yes |
no |
PIKO IQ 8.5 |
yes |
no |
PIKO IQ 10 |
yes |
no |
Configuration
1) /smarthome/etc/plugin.yaml
Enable the plugin in plugin.yaml, type in the inverters IP address and configure the ModBus Port and update cycle(seconds).
Kostalmodbus:
plugin_name: kostalmodbus
inverter_ip: 'XXX.XXX.XXX.XXX'
modbus_port: '1502'
update_cycle: '20'
2) /smarthome/items/kostal.yaml
Create an item based on the template /files/kostal_item_template.yaml
Examples
Thats it! Now you can start using the plugin within SmartVisu. For example:
Get data from inverter:
<p>Daily yield: {{ basic.value('DailyYield', 'Kostal.Inverter.kostal_322') }} Wh</p>
/** Get the daily yield (num)*/
<p>Total DC power: {{ basic.value('TotalDCPower', 'Kostal.Inverter.kostal_100') }} W</p>
/** Get the current total DC power (num)*/
The following data are stored in the respective items:
Addr (dec) |
Description |
Format |
Unit |
---|---|---|---|
kostal_06 |
Inverter article number |
String |
- |
kostal_14 |
Inverter serial number |
String |
- |
kostal_30 |
Number of bidirectional converter |
U16 |
- |
kostal_32 |
Number of AC phases |
U16 |
- |
kostal_34 |
Number of PV strings |
U16 |
- |
kostal_36 |
Hardware-Version |
U16 |
- |
kostal_38 |
Software-Version Maincontroller (MC) |
String |
- |
kostal_46 |
Software-Version IO-Controller (IOC) |
String |
- |
kostal_54 |
Power-ID |
U16 |
- |
kostal_56 |
Inverter state2 |
U16 |
- |
kostal_98 |
Temperature of controller PCB |
Float |
°C |
kostal_100 |
Total DC power W |
Float |
W |
kostal_104 |
State of energy manager3 |
U32 |
- |
kostal_106 |
Home own consumption from battery |
Float |
W |
kostal_108 |
Home own consumption from grid |
Float |
W |
kostal_110 |
Total home consumption Battery |
Float |
Wh |
kostal_112 |
Total home consumption Grid |
Float |
Wh |
kostal_114 |
Total home consumption PV |
Float |
Wh |
kostal_116 |
Home own consumption from PV |
Float |
W |
kostal_118 |
Total home consumption |
Float |
Wh |
kostal_120 |
Isolation resistance |
Float |
Ohm |
kostal_122 |
Power limit from EVU |
Float |
% |
kostal_124 |
Total home consumption rate |
Float |
% |
kostal_144 |
Worktime s Float |
Float |
Seconds |
kostal_150 |
Actual cos |
Float |
cos |
kostal_152 |
Grid frequency |
Float |
Hz |
kostal_154 |
Current Phase 1 |
Float |
A |
kostal_156 |
Active power Phase 1 |
Float |
W |
kostal_158 |
Voltage Phase 1 |
Float |
V |
kostal_160 |
Current Phase 2 |
Float |
A |
kostal_162 |
Active power Phase 2 |
Float |
W |
kostal_164 |
Voltage Phase 2 |
Float |
V |
kostal_166 |
Current Phase 3 |
Float |
A |
kostal_168 |
Active power Phase 3 |
Float |
W |
kostal_170 |
Voltage Phase 3 |
Float |
V |
kostal_172 |
Total AC active power |
Float |
W |
kostal_174 |
Total AC reactive power |
Float |
Var |
kostal_178 |
Total AC apparent power |
Float |
VA |
kostal_190 |
Battery charge current |
Float |
A |
kostal_194 |
Number of battery cycles |
Float |
- |
kostal_200 |
Actual battery charge (-) / discharge (+) current |
Float |
A |
kostal_202 |
PSSB fuse state5 |
Float |
- |
kostal_208 |
Battery ready flag |
Float |
- |
kostal_210 |
Act. state of charge |
Float |
% |
kostal_214 |
Battery temperature |
Float |
°C |
kostal_216 |
Battery voltage |
Float |
V |
kostal_218 |
Cos φ (powermeter) |
Float |
cos |
kostal_220 |
Frequency (powermeter) |
Float |
Hz |
kostal_222 |
Current phase 1 (powermeter) |
Float |
A |
kostal_224 |
Active power phase 1 (powermeter) |
Float |
W |
kostal_226 |
Reactive power phase 1 (powermeter) |
Float |
Var |
kostal_228 |
Apparent power phase 1 (powermeter) |
Float |
VA |
kostal_230 |
Voltage phase 1 (powermeter) |
Float |
V |
kostal_232 |
Current phase 2 (powermeter) |
Float |
A |
kostal_234 |
Active power phase 2 (powermeter) |
Float |
W |
kostal_236 |
Reactive power phase 2 (powermeter) |
Float |
Var |
kostal_238 |
Apparent power phase 2 (powermeter) |
Float |
VA |
kostal_240 |
Voltage phase 2 (powermeter) |
Float |
V |
kostal_242 |
Current phase 3 (powermeter) |
Float |
A |
kostal_244 |
Active power phase 3 (powermeter) |
Float |
W |
kostal_246 |
Reactive power phase 3 (powermeter) |
Float |
Var |
kostal_248 |
Apparent power phase 3 (powermeter) |
Float |
VA |
kostal_250 |
Voltage phase 3 (powermeter) |
Float |
V |
kostal_252 |
Total active power (powermeter) |
Float |
W |
kostal_254 |
Total reactive power (powermeter) |
Float |
Var |
kostal_256 |
Total apparent power (powermeter) |
Float |
VA |
kostal_258 |
Current DC1 |
Float |
A |
kostal_260 |
Power DC1 |
Float |
W |
kostal_266 |
Voltage DC1 |
Float |
V |
kostal_268 |
Current DC2 |
Float |
A |
kostal_270 |
Power DC2 |
Float |
W |
kostal_276 |
Voltage DC2 |
Float |
V |
kostal_278 |
Current DC3 |
Float |
A |
kostal_280 |
Power DC3 |
Float |
W |
kostal_286 |
Voltage DC3 |
Float |
V |
kostal_320 |
Total yield |
Float |
Wh |
kostal_322 |
Daily yield |
Float |
Wh |
kostal_324 |
Yearly yield |
Float |
Wh |
kostal_326 |
Monthly yield |
Float |
Wh |
kostal_384 |
Inverter network name |
String |
- |
kostal_420 |
IP-address |
String |
- |
kostal_428 |
IP-subnetmask |
String |
- |
kostal_436 |
IP-gateway |
String |
- |
kostal_446 |
IP-DNS1 |
String |
- |
kostal_454 |
IP-DNS2 |
String |
- |
kostal_512 |
Battery gross capacity |
U32 |
Ah |
kostal_514 |
Battery actual SOC |
U16 |
% |
kostal_515 |
Firmware Maincontroller (MC) |
U32 |
- |
kostal_517 |
Battery Manufacturer |
String |
- |
kostal_525 |
Battery Model ID |
U32 |
- |
kostal_529 |
Work Capacity |
U32 |
Wh |
kostal_531 |
Inverter Max Power |
U16 |
W |
kostal_535 |
Inverter Manufacturer |
String |
- |
kostal_559 |
Inverter Serial Number |
String |
- |
kostal_575 |
Inverter Generation Power (actual) |
S16 |
W |
kostal_577 |
Generation Energy |
U32 |
Wh |
kostal_582 |
Actual battery charge/discharge power |
S16 |
W |
kostal_586 |
Battery Firmware |
U32 |
- |
kostal_588 |
Battery Type6 |
U16 |
- |
kostal_768 |
Productname |
String |
- |
kostal_800 |
Power class |
String |
- |
kostal_1056 |
Total DC PV energy (sum of all PV inputs) |
Float |
Wh |
kostal_1058 |
Total DC energy from PV1 |
Float |
Wh |
kostal_1060 |
Total DC energy from PV2 |
Float |
Wh |
kostal_1062 |
Total DC energy from PV3 |
Float |
Wh |
kostal_1064 |
Total energy AC-side to grid |
Float |
Wh |
kostal_1066 |
Total DC power (sum of all PV inputs) |
Float |